What Is an Electrical Installation Condition Report (EICR)?

26 August 2026

In This Blog

    Property owners, landlords, and facilities managers must understand the electrical installation condition report to maintain legal compliance. An electrical installation condition report (EICR) assesses the safety of fixed electrical wiring and components within a building. It confirms whether internal circuits, socket outlets, consumer units, and connected gear remain safe for daily use.

    Just like an MOT tests a vehicle, a periodic inspection evaluates your building's electrical safety. A qualified electrician assesses your setup against modern safety rules and records every finding in an official document. For full details on legal requirements and schedules, review our EICR testing and compliance services.

    A qualified electrician inspecting a commercial consumer unit to issue an electrical installation condition report EICR under BS 7671 rules.

    Scope of an EICR Assessment

    An EICR focuses on permanent electrical systems, not plug-in appliances.

    During the assessment, a qualified electrician has the fixed infrastructure inspected and tested, including:

    • Consumer units (distribution boards) and protective circuit breakers
    • Internal wiring and main power cables throughout the property
    • Hardwired switches, socket outlets, and light fittings
    • Earthing arrangements and main protective bonding
    • Signs of thermal damage, heavy wear, overloading, or physical decay
    • Non-compliance with current IET wiring regulations (BS 7671)

    The electrician begins with a visual inspection, followed by live and dead circuit tests. Engineers must isolate certain circuits during testing, which causes brief, planned power outages.

    EICR Observation Codes and Results Explained

    The report uses clear observation codes to flag defects. Understanding these codes helps you gauge the condition of the electrics.

    • Code C1 Danger Present: The electrician found an immediate risk of injury or electric shock. You must take immediate remedial action to make the setup safe.
    • Code C2 Potentially Dangerous: The issue is not an instant danger, but you must complete urgent repairs to remove the potential risk.
    • Code C3 Improvement Recommended: The electrician noted minor deficiencies that do not meet modern standards, but pose no immediate safety risk.
    • Code FI (Further Investigation): The engineer identified a potential fault that requires a closer technical look without delay.

    The electrician declares the overall outcome as either Satisfactory (Pass) or Unsatisfactory (Fail). Any C1, C2, or FI code makes the report unsatisfactory, requiring you to complete mandatory repairs before achieving compliance. A satisfactory result confirms your setup meets acceptable electrical safety standards, though minor recommendations (C3) may remain.

    Legislative Compliance and Duty of Care

    Regular testing protects building occupants from severe hazards. Faulty wiring causes structural fires and electric shocks.

    The law explicitly states that an installation condition report is legally required for property owners and social housing providers. Across private rental properties in England, landlords must ensure their properties meet electrical safety standards at all times. Landlords must give a copy of the report to each existing tenant within 28 days of the test, and to prospective tenants before they move in. Commercial property operators and local authorities must also meet strict health and safety laws to keep staff safe.

    Key benefits include:

    • Clear, audit-ready compliance records for safety bodies
    • Fewer sudden circuit failures and emergency call-outs
    • Solid evidence of due diligence for insurers and legal claims
    • Total protection for tenants, staff, and visitors

    Inspection Frequencies for Properties

    Recommended testing intervals depend on property type and usage:

    • Private Rental Properties: At least once every five years, or at each change of tenancy
    • Commercial Premises: Typically every five years
    • Industrial Buildings: Every three years due to heavy daily use
    • Owner-Occupied Homes: Recommended every ten years

    You should also book a periodic inspection after major building work or if you notice warning signs, such as tripping breakers or heat damage on fittings.

    Managing an Unsatisfactory EICR Outcome

    An unsatisfactory report lists the exact fixes you need.

    After testing, your electrician explains each code and quotes for the necessary repairs. Once you resolve all C1 and C2 issues, the electrician issues an official certificate confirming that your building meets statutory rules. Landlords must complete mandatory repairs within 28 days of the test, or sooner if the report specifies.

    Specialist Electrical Compliance from UKGS

    An EICR relies entirely on the skill of your inspecting electrician. Facilities managers need accredited contractors who deliver clear, defensible reports.

    UKGS brings over 25 years of specialist property services experience across the Midlands. We partner with local authorities, housing associations, commercial landlords, and facilities teams. Our certified engineering teams run thorough inspections, deliver plain-English reports, and complete all required repairs to keep your buildings compliant and safe.

     



    We can help with your EICR

    Contact our compliance specialists today to book an electrical inspection for your property portfolio.